Harvel Clear pipe and fittings are manufactured in IPS sizes to
Schedule 40 dimensions for optimum performance. This provides sufficient
wall thickness for most pressure applications without jeopardizing
clarity. As a rigid PVC piping, Harvel Clear PVC maintains its integrity
in harsh environments. It is suitable for use in both positive and
negative pressure applications (i.e., vacuum service).
As with all schedules of thermoplastic pipe, pressure rating is
dependent on the pipe diameter selected as well as the operating
temperature of the system. As temperatures rise, the pressure rating
of the system decreases. Smaller diameter piping can withstand higher
pressures than large diameter piping. Refer to the table below for
dimensions, tolerances and pressure ratings.
Dimensions and Pressure Ratings
|
Nominal Pipe Size (in) |
O.D. |
Average I.D. |
Min. Wall |
Nominal Wt./Ft. |
Max. W.P. PSI** |
1/4" |
0.540 |
0.344 |
0.088 |
0.086 |
390 |
3/8" |
0.675 |
0.473 |
0.091 |
0.115 |
310 |
1/2" |
0.840 |
0.602 |
0.109 |
0.170 |
300 |
3/4" |
1.050 |
0.804 |
0.113 |
0.226 |
240 |
1" |
1.315 |
1.029 |
0.133 |
0.333 |
220 |
1-1/4" |
1.660 |
1.360 |
0.140 |
0.450 |
180 |
1-1/2" |
1.900 |
1.590 |
0.145 |
0.537 |
170 |
2" |
2.375 |
2.047 |
0.154 |
0.720 |
140 |
2-1/2" |
2.875 |
2.445 |
0.203 |
1.136 |
150 |
3" |
3.500 |
3.042 |
0.216 |
1.488 |
130 |
3-1/2" |
4.000 |
3.521 |
0.226 |
1.789 |
120 |
4" |
4.500 |
3.998 |
0.237 |
2.118 |
110 |
6" |
6.625 |
6.031 |
0.280 |
3.733 |
90 |
6" X 1/8 |
6.625 |
6.335 |
0.110 |
1.647 |
45 |
8" |
8.625 |
7.942 |
0.322 |
5.619 |
80 |
10" |
10.750 |
9.976 |
0.365 |
7.966 |
70 |
|
12" |
12.750 |
11.889 |
0.406 |
10.534 |
70 |
|
|